- Homepage
- Technical Insights
- Axial Fan Impeller: What Is It And How It Works
Axial Fan Impeller: What Is It And How It Works
An axial fan impeller is the part of an axial fan that does the actual work: its blades take the rotation of the motor and turn it into an airflow that runs straight along the shaft axis. Hub, blade profile, materials and pitch decide how much air the fan moves, against how much resistance, at what temperature and for how long.
In this article:
- What is an axial fan impeller?
- How does it work?
- Hub, blades and materials
- How to effectively control an axial fan impeller
- The axial fan impellers by CBI Group
- Choosing the right axial fan impeller
What Is An Axial Fan Impeller?
An axial fan impeller is a central hub carrying a set of blades, mounted directly on the motor shaft or driven through belts and pulleys. As it rotates, it draws air in on one side and discharges it on the other, along the same axis around which the shaft turns.
This is the key difference from a centrifugal fan impeller, which takes air in axially and releases it at right angles. Because the air keeps a straight path, axial impellers are the natural choice for large air volumes, typically at low to medium pressure: roof ventilation, industrial process ventilation, tunnels and metro lines.
How Does It Work?
As the impeller turns, the blades meet the air at an angle and create a pressure difference between their two faces: the air is pushed forward along the axis and leaves the impeller with more velocity and more pressure than it had at the inlet.
How much energy the impeller transfers depends on blade profile, rotational speed and blade angle, which also determines where the fan operates on its curve.
We look at it in detail in What is the blade angle of an axial fan blade?
The profile also sets the direction in which the impeller can work. On unidirectional fans the aerofoil is non-symmetrical, shaped to perform in a single direction. Reversible fans, used in many industrial applications and in tunnels and metro lines, where air has to be moved both ways, use symmetrical profiles so that performance stays close in both directions.
Contact us
Hub, Blades And Materials
-
The hub transmits torque from the shaft to the blades and holds each blade at its set angle. In direct-drive impellers it can include a steel or cast-iron insert for direct coupling to the shaft.
-
The blades change in number, material and manufacturing process according to size and duty. In CBI impellers they are made from aluminium alloys, either pressure die-cast or extruded. The number of blades can also change with the size of the impeller.
- The position of the motor sets limits of its own. With the motor in the airflow, the temperature and corrosiveness of the fluid are restricted; with the motor out of the airflow, driven through belts and pulleys, the fan can handle fluids up to 180 °C. In CBI belt-driven fans, an internal belt guard keeps the belts out of contact with the fluid.
Tunnel and metro applications push the limits further, because the impeller has to keep working during emergency smoke and heat extraction: here fans are certified to EN 12101-3, with ratings up to 400 °C for 2 hours.
How To Effectively Control An Axial Fan Impeller
As with any industrial fan, control means adjusting speed, air volume and pressure to the real needs of the installation. Axial impellers add one more lever: blade pitch.
- Variable Frequency Drives (VFDs): they adjust motor speed and, with it, the flow and pressure delivered by the impeller;
- blade pitch adjustment: changing the pitch angle of the blades matches the fan to the installation at low cost; depending on the design, the pitch can be adjusted only with the fan stopped;
- inlet vane control: it regulates the air entering the impeller;
- dampers: installed at the inlet or outlet, manual or motorised, they regulate or shut off the airflow, while non-return dampers prevent backflow.
The Axial Fan Impellers by CBI Group
Each CBI axial series combines a specific impeller design with a specific duty, from general industrial ventilation to emergency smoke extraction. Special executions, such as AISI stainless steel or ATEX execution on request, vary by model.
GAT series
The fans are engineered for high performance and reliability, with flow from pulley to impeller, suitable for horizontal or vertical installation, featuring heavy-gauge galvanized steel casings and high-efficiency aluminum impellers with low noise levels.
Discover more
AXL series
The AXL series includes high-performance axial fans designed for high airflow, low pressure losses, low noise and long service life in industrial and infrastructure ventilation systems.
Discover more
GAV/GAX series
The GAV/GAX series features axial fans with wing-profile, adjustable-pitch blades, engineered for high performance and low noise, with sturdy galvanized steel casings and direct-coupled impellers to minimize maintenance and costs.
Discover more
EFA series
Discover more
CBJET series
The CBJET series is designed for tunnel and gallery installations, ensuring long-term reliability, smoke extraction capability in case of fire, and EN 12101-3 certification up to 400°C/2h.
Discover moreChoosing The Right Axial Fan Impeller
Selecting an axial impeller means reading several variables together: the air volume and pressure the installation demands, the temperature and nature of the fluid, whether the flow has to be reversed, and how the fan will be regulated over time. Hub, blade profile, material and pitch are the answer to those questions, and getting them right from the start is what makes an axial fan reliable in the long run. CBI designs, builds and services its fans in-house, from the first selection to revamping and spare parts.